  • On demand hot water - no delay
  • Cut energy waste - Flow switch activates heater only when water is running, no standby heat loss
  • 99% Efficient, .99 energy factor
  • Endless hot water - No storage capacity to deplete
  • Reduces installation cost and material - No T&P valve required (check local codes)
  • Glass reinforced heating chambers in a unique flow path ensures optimum heat transfer and extended element life
  • Easy Installation - Simple NPT fittings that require no soldering. Unit mounts directly to the wall with common hardware.
  • Prevents Legionella bacteria growth
  • Reduces calcification and sedimentation
  • Field Serviceable - All major component are field replaceable and readily available
  • Proudly made In the USA
Model GPM Turn On Minimum Operating Pressure Max Pressure Rating Power Volts Phase Amperage Recommended Wire Size Water Connection Plumbing Configuration
Model GPM Turn On Minimum Operating Pressure Max Pressure Rating Power Volts Phase Amperage Recommended Wire Size Water Connection Plumbing Configuration
EX280T2T 0.7 25 PSI 150 PSI 28.5 240V Single 119 3 sets of 8AWG 3/4'' Bottom
EX280T2T DI 0.7 25 PSI 150 PSI 28.5 240V Single 119 3 sets of 8AWG 3/4'' Bottom
EX280T2T DI N4 0.7 25 PSI 150 PSI 28.5 240V Single 119 3 sets of 8AWG 3/4'' Bottom
EX280T2T DI N4X 0.7 25 PSI 150 PSI 28.5 240V Single 119 3 sets of 8AWG 3/4'' Bottom
EX280T2T FS 0.7 25 PSI 150 PSI 28.5 240V Single 119 3 sets of 8AWG 3/4'' Bottom
EX280T2T FS N4 0.7 25 PSI 150 PSI 28.5 240V Single 119 3 sets of 8AWG 3/4'' Bottom
EX280T2T FS N4X 0.7 25 PSI 150 PSI 28.5 240V Single 119 3 sets of 8AWG 3/4'' Bottom
EX280T2T ML 0.3 25 PSI 150 PSI 28.5 240V Single 119 3 sets of 8AWG 3/4'' Bottom
EX280T2T ML N4 0.3 25 PSI 150 PSI 28.5 240V Single 119 3 sets of 8AWG 3/4'' Bottom
EX280T2T ML N4X 0.3 25 PSI 150 PSI 28.5 240V Single 119 3 sets of 8AWG 3/4'' Bottom
EX280T2T N4 0.7 25 PSI 150 PSI 28.5 240V Single 119 3 sets of 8AWG 3/4'' Bottom
EX280T2T N4X 0.7 25 PSI 150 PSI 28.5 240V Single 119 3 sets of 8AWG 3/4'' Bottom
EX280T2T S 0.7 25 PSI 150 PSI 28.5 240V Single 119 3 sets of 8AWG 3/4'' Bottom
EX280T2T S N4 0.7 25 PSI 150 PSI 28.5 240V Single 119 3 sets of 8AWG 3/4'' Bottom
EX280T2T S N4X 0.7 25 PSI 150 PSI 28.5 240V Single 119 3 sets of 8AWG 3/4'' Bottom
EX280T3 0.7 25 PSI 150 PSI 28.5 240V Single 119 3 sets of 8AWG 3/4'' Bottom
EX280T3 FS 0.7 25 PSI 150 PSI 28.5 240V Single 119 3 sets of 8AWG 3/4'' Bottom
EX280T3 FS N4 0.7 25 PSI 150 PSI 28.5 240V Single 119 3 sets of 8AWG 3/4'' Bottom
EX280T3 FS N4X 0.7 25 PSI 150 PSI 28.5 240V Single 119 3 sets of 8AWG 3/4'' Bottom
EX280T3 N4 0.7 25 PSI 150 PSI 28.5 240V Single 119 3 sets of 8AWG 3/4'' Bottom
EX280T3 N4X 0.7 25 PSI 150 PSI 28.5 240V Single 119 3 sets of 8AWG 3/4'' Bottom
EX280T3 S 0.7 25 PSI 150 PSI 28.5 240V Single 119 3 sets of 8AWG 3/4'' Bottom
EX280T3 S N4 0.7 25 PSI 150 PSI 28.5 240V Single 119 3 sets of 8AWG 3/4'' Bottom
EX280T3 S N4X 0.7 25 PSI 150 PSI 28.5 240V Single 119 3 sets of 8AWG 3/4'' Bottom
´╗┐